Understanding EPSON TWAIN Pro Features / Using the Preview Window

Using the Adjust Buttons

Auto Exposure
Image Controls
Tone Correction
Color Adjustment
Reset
Auto Focus
Manual Focus

The Adjust buttons described in this section offer you a powerful means of improving image quality. All adjustments you make with these tools are shown in the previewed image. For further information on using these buttons to optimize scanning, see Recommended Adjustment Order.


Auto Exposure


Image Controls


Tone Correction


Color Adjustment


Reset


Auto Focus


Manual Focus

Auto Exposure

Click the Auto Exposure button to optimize the exposure for the entire image, or for areas surrounded by active or selected marquees. This feature adjusts the Gamma, Highlight, and Shadow settings automatically.

Note:
  • Select Continuous Auto Exposure on the Color menu of the Configuration dialog box to set the Auto Exposure feature to work whenever you click the Preview button, modify the size of the previewed image with the zoom feature, make a marquee, or change the size or location of a marquee. See Color menu for more information.
  • The Auto Exposure feature is not available when the Pixel Depth is set to Black & White and Auto Area Segmentation is not selected in the Image Type dialog box.
  • The Auto Exposure feature overrides any Gamma, Highlight, or Shadow settings made in the Image Controls dialog box. Be sure to use Auto Exposure before making any of the these settings.
  • The Auto Exposure feature is automatically activated when scanning without previewing.


[Top]

Image Controls

Click the Image Controls button to open the Image Controls dialog box. This dialog box allows you to make a wide range of image adjustments, as described below.

Note:
  • The Image Controls settings are not available when Text Enhancement Technology is selected in the Image Type dialog box.
  • The Image Controls button is unavailable when one or more marquees are selected in addition to the active marquee.
  • The Image Controls settings are optimized automatically when you scan without previewing.
  • If Pixel Depth is set to Black & White and Halftone is set to None in the Image Type dialog box, all settings except Threshold are not available.
  • The Gamma, Highlight, and Shadow settings are overridden by the Auto Exposure feature. Be sure to use the Auto Exposure feature before making these settings. See Auto Exposure for more information on using this feature.

Exposure

The Exposure setting lightens or darkens an image. You can select from -10 (darkest) to 20 (brightest) by moving the slider.

The Exposure and Highlight settings are related. When the Exposure setting is changed, the Highlight value also changes automatically.

Gamma

The Gamma setting allows you to adjust the mid-tones in an image. You can select from 0.5 (darkest) to 5.0 (brightest) by moving the slider.

For further information on using the Gamma setting to optimize scanning, see Making the Gamma setting.

Highlight

The Highlight setting allows you to adjust the brightness level of the brightest parts of an image. You can select from 61 to 490 by moving the slider.

Click the eyedropper button beneath the slider, and the mouse pointer changes to an eyedropper. Move the eyedropper over the previewed image, and click a bright area. The eyedropper "picks up" the color from that area, and uses it as the highlight for the entire image. Click Cancel to restore the original image.

For further information on using the Highlight setting to optimize scanning, see Making the Highlight setting.

Shadow

The Shadow setting allows you to adjust the darkness level of the darkest parts of an image. You can select from 0 to 60 by moving the slider.

Click the eyedropper button beneath the slider, and the mouse pointer changes to an eyedropper. Move the eyedropper over the previewed image, and click a dark area. The eyedropper "picks up" the color from that area, and uses it as the shadow for the entire image. Click Cancel to restore the original image.

For further information on using the Shadow setting to optimize scanning, see Making the Shadow setting.

Threshold

Available only when Pixel Depth is set to Black & White and Halftone is set to None in the Image Type dialog box. The scanner scans gray shades as either black or white using this setting, and is useful for optical character reading (OCR).

You can select from 0 (lightest) to 255 (darkest) by moving the slider.


[Top]

Tone Correction

Clicking the Tone Correction button opens the Tone Correction dialog box. The settings described in this section allow you to adjust the tonal relationship between the original image and its reproduction on a monitor or printer.

Note:
  • The Tone Correction button is unavailable when one or more marquees are selected in addition to the active marquee.
  • The Linear setting is the default Tone Correction setting.
  • The Tone Correction feature is not available when Pixel Depth is set to Black & White, Halftone is set to None, and Text Enhancement Technology is selected in the Image Type dialog box.

To save your Tone Correction settings, type a new name in the Tone Curve Name box and click Save. To delete a setting from the Tone Curve Name list, select the setting and click Delete.

To apply your Tone Correction settings, click OK. To restore the original settings, click Cancel.

For further information on using Tone Correction to optimize scanning, see Making tone curve settings.

Tone Curve editor

The editor allows you to customize tone correction. Drag points on the tone curve to adjust the tone value. You can edit up to five tonal elements.

Output options

If you select the check box for a specific point, such as 1/4 Tone or Midtone, you can move that point and it will remain where you leave it; it will not be affected by the movement of other points on the curve. If the check box is cleared, the point will be affected by the movement of other points.

Channels options

You can select the combined red, green, and blue (RGB) channel to modify all colors, or select each of these colors separately.

Note:
If Pixel Depth is set to Black & White or 8-bit Gray in the Image Type dialog box, you can only select the combined RGB channel option.

Tone Curve Name list

Select a tone correction setting from this list. The custom settings you have saved appear in this list.

For further information on using the Tone Curve Name list to optimize scanning, see Applying a preset tone curve.


[Top]

Color Adjustment

Click the Color Adjustment button in the Preview window to open the Color Adjustment dialog box, where you can make Gray Balance Intensity and Saturation settings.

Note:
  • The Color Adjustment button is unavailable when one or more marquees are selected in addition to the active marquee.
  • If Image Type setting is not 42-bit Color (HiFi), 24-bit Color (Std), or 24-bit Color De-screening, or Pixel Depth is set to 8-bit Gray or Black & White, the Color Adjustment feature is not available.

Gray Balance Intensity

The Gray Balance Intensity setting removes unwanted color casts and tints by balancing color saturation.

Click the eyedropper button beneath the slider. The mouse pointer changes to an eyedropper. Then click the color you want to represent as gray. The eyedropper "picks up" the color and displays it in the box beside the eyedropper button. You can then correct the cast level for that color from 0 to 100 by moving the slider. The corrected color appears in the box on the right, and the effect shows up immediately in the previewed image. Click Cancel to restore the original image.

Note:
You can use the Auto Exposure feature to automatically adjust Gray Balance Intensity when Document is selected as the Auto Exposure Option in the Image Type dialog box. To change the Auto Exposure Option setting, see Auto Exposure Option.

Saturation

Saturation is the property that defines color depth. Select a saturation level from -100 (less color) to 100 (more color) by moving the slider.


[Top]

Reset

Click the Reset button to return any Adjust button settings you made to their default settings. If you did not alter any settings, this button is not available.


[Top]

Auto Focus

Click the Auto Focus button on the Preview window to set the focus position.


[Top]

Manual Focus

Click the Manual Focus button on the Preview window to determine where the focus should be. This may help improve the quality of your image. When you click this button, the following window appears.

Auto Focus

Clicking the Auto Focus button adjust the focus position automatically. This works exactly the same way the Auto Focus button in the Adjust dialog box works.

Focus Position

You can select from-2.0 (Lowest) to 6.0 (highest) by moving the slider, clicking the left or right arrow, or typing a value from -2.0 to 6.0 in increments of 0.1 in the Focus Position box. By adjusting the focus position, you can reduce the occurrence of moiré patterns when scanning.

Note:
  • If TPU (for Neg. Film or for Pos. Film) is selected as the Document Source, the value of the focus position is automatically set to 2.5. If Flatbed or ADF (Single-sided or Double-sided) is selected, the value is automatically set to 0.
  • If you set the film to be scanned using film holders, you do not need to change the focus setting. If you set the film directly on the scanner's document table, it is recommended to change the focus position to 0.0.

Selected area for focusing window

This window shows a preview image of the active marquee. If there is no marquee in the Preview window, the focus marquee window shows a full preview image. To change the image in the focus marquee window, change the marquee or the image in the Preview window.

Focus Line

The focus line appears at the center of the focus marquee window (default). If you move the cursor over the focus line, the cursor will change to a "hand" cursor. You can then move the focus line by clicking and dragging the "hand" cursor to a new part of the image.

Confirm

Click this button to compare the new image that you just modified image (shown in the Result window) with the unmodified image (shown in the Before window).

Result window

This window shows the image whose focus line position you just modified.

Before window

This window shows the image with the focus line in the default position. The focus line determines what point of the image is used.


[Top]