Reference Guide
|
|
How to / Replacing Consumable Products
Photoconductor Unit
Handling precautions
Replacing the photoconductor unit
Prepare a new photoconductor unit for replacement when you see a message informing you to do so. The photoconductor unit has a slot that accommodates the waste toner collector.
When you purchase a photoconductor unit, it always comes with a waste toner collector because it usually needs replacement at the same time as the photoconductor unit. However, the waste toner collector is also sold individually as you may need to replace it separately depending on use.
Handling precautions
Always pay attention to the following handling precautions before replacing the photoconductor unit.
-
When replacing the photoconductor unit, avoid exposing it to room light any longer than necessary.
-
Be sure not to scratch the surface of the drum. Also, avoid touching the drum, since oil from your skin may permanently damage its surface and affect print quality.
-
To get the best print quality, do not store the photoconductor unit in an area subject to direct sunlight, dust, salty air, or corrosive gases (such as ammonia). Avoid locations subject to extreme or rapid changes in temperature or humidity.
|
Warning:
|
| -
Do not dispose of the used photoconductor unit in fire, as it may explode and cause injury. Dispose of it according to local regulations.
|
| -
Keep the photoconductor unit out of the reach of children.
|
[Top]
Replacing the photoconductor unit
Follow these steps to replace the photoconductor unit.
|
Turn off the printer.
|
|
Open the front cover.
|
|
Turn the large lever 90 degrees counterclockwise.
|
|
Turn the small lever to the right.
|
|
Pull the photoconductor unit about 20 cm out of the printer.
|
|
Hold the handle at the top of the photoconductor unit and gently pull it all the way out.
|
|
Take the new photoconductor unit out of its package and unwrap the protective sheet while holding the handle.
|
|
Insert the photoconductor unit as shown below.
|
|
Turn the small lever to the left.
|
|
Turn the large lever 90 degrees clockwise.
|
|
Close the front cover.
|
[Top]
Version 1.00E, Copyright © 2002, SEIKO EPSON CORPORATION |