Setup & Maintenance / Replacing Consumable Products
Fuser Unit
Prepare a new fuser unit for replacement when you get a message informing you to do so.
Handling precautions
Note the following handling precautions before replacing the fuser unit:
Do not touch the surface of the fuser unit. Doing so may impair print quality.
|
Warning:
|
| -
The fuser unit can be very hot if the printer has been in use. Turn the printer off and wait for 30 minutes until the temperature has subsided before replacing the fuser unit.
|
|
| -
Do not dispose of the used fuser unit in fire, as it may explode and cause injury. Dispose of it according to local regulations.
|
|
| -
Keep the fuser unit out of the reach of children.
|
|
Replacing the fuser unit
Follow these steps to replace the fuser unit.
|
Turn off the printer, and wait for 30 minutes until the temperature has subsided.
|
|
Press the latch on cover B and open the cover.
|
|
Push the lever down and raise cover D.
|
|
Unlock the locks on both sides of the fuser unit.
|
|
Lift the fuser unit out of the printer as shown below.
|
|
Take the new fuser unit out of its package.
|
|
Hold the new fuser unit by the handles and lower it into the printer making sure that the guide posts slide into the holes on the bottom of the unit.
|
|
Lock the fuser unit.
|
| |
Note:
|
| |
Make sure that the locks are completely in the locked position.
|
|
|
Close covers D and B.
|