Reference Guide
|
|
How to / Replacing Consumable Products
Fuser Oil Roll
Prepare a new fuser oil roll for replacement when the you see a message informing you of to do so.
Handling precautions
Always pay attention to the following handling precautions before replacing the fuser oil roll:
-
Do not touch the white roll surface. It is covered with silica oil.
-
If oil gets on your skin or clothes, wash it off immediately.
-
The roll should always be kept horizontal. Do not tilt or lean it against anything. Doing so might cause oil to leak and impair print quality.
-
Keep the fuser oil roll out of the reach of children.
|
Warning:
|
| -
Do not dispose of the used fuser oil roll in fire, as it may explode and cause injury or fire.Dispose of it according to local regulations.
|
| -
The fuser oil roll can be very hot if the printer has been in use. Turn the printer's power off and wait till the temperature has subsided before changing the fuser oil roll.
|
Replacing the fuser oil roll
Follow these steps to replace the fuser oil roll:
|
Push the lever and lift the printer's top cover.
|
|
Turn the two fuser oil roll levers inward, as shown below.
|
|
Hold the fuser oil roll by the handle and lift it gently out of the printer.
|
|
Remove the new fuser oil roll from its package.
|
| |
Note
|
| |
Do not touch the white roll surface.
|
|
Hold the new fuser oil roll by the handle and lower it into the printer, making sure that the two side flaps fit into their corresponding slots on the fuser unit.
|
|
Turn the two levers outward such that they rest above the fuser oil roll, as shown below.
|
|
Gently close the top cover until it clicks.
|