EPSON

Scanner Specifications

Note:
Specifications are subject to change without notice.

General

Scanner type
Flatbed color
Photoelectric device
Color CCD line sensor
Effective pixels
7,020 × 10,200 pixels at 600 dpi
Scanning area may be restricted if resolution setting is large.
Document size
297 × 432 mm (11.7 × 17.0 inches) A3 or US B size
Scanning resolution
600 dpi (main scan)
1200 dpi with Micro Step (sub scan)
Output resolution
50 to 9600 dpi
Image data
16 bits per pixel per color internal
1 to 8 bits per pixel per color external
Interface
One USB 2.0 Hi-speed port
SCSI (50-contact high-density)
Light source
Xenon gas fluorescent lamp
Note:
Optional optical resolution is the maximum scan resolution of the CCD elements, using the definition of ISO 14473. ISO 14473 defines optical resolution as the fundamental sampling rate of the scan sensor.

Mechanical

Dimensions
Width: 656.0 mm (25.8 inches)
Depth: 458.0 mm (18.0 inches)
Height: 158.0 mm (6.2 inches)
Weight
Approx. 13.5 kg (29.8 lb)

Electrical

Scanner

Rated voltage
Universal Power Supply AC 100 to 240 V (AC ±10% V)
Rated input current
0.8 to 0.3 A
Power consumption
50 W operating (without optional ADF)
75 W operating (with optional ADF)
6.2 W or lower in sleep mode (without optional ADF)
0.1 W or lower in power off mode (without optional ADF)

Environmental

Temperature
Operating
5 to 35 ˚C (41 to 95 ˚F)
Storage
–25 to 60 ˚C (–13 to 140 ˚F)
Humidity
Operating
10 to 80%, without condensation
Storage
10 to 85%, without condensation
Operating conditions
Ordinary office or home conditions.
Avoid operating the scanner in direct sunlight, near a strong light source, or in extremely dusty conditions.

Interfaces

USB Interface

Interface type
Universal Serial Bus Specification Revision 2.0
Electrical standard
Full Speed mode (12 Mbits per second) and Hi-Speed mode (480 Mbits per second) of Universal Serial Bus Specification Revision 2.0.
Connector type
One Type B port

SCSI Interface

Interface type
ANSI X3T9.2/375R Revision 10L (SCSI2)
Functions
BUS FREE Phase
ARBITRATION phase
SELECTION/RESELECTION phase
COMMAND phase*
DATA IN phase
DATA OUT phase
STATUS phase
MESSAGE IN phase
MESSAGE OUT phase
ATTENTION CONDITION
RESET CONDITION
Connector type
Two connectors (50-contact high-density)
* Logical Unit Number is fixed to 0 and command link function is not supported.

Standards and Approvals

U.S. model:
Safety
UL60950-1
CAN/CSA-C22.2 No. 60950-1
EMC
FCC Part 15 Subpart B Class B
CAN/CSA-CEI/IEC CISPR22 Class B
European model:
Low Voltage Directive 2006/95/EC
EMC Directive 2004/108/EC
EN 60950-1
EN 55022 Class B
EN 55024
EN 61000-3-2
EN 61000-3-3