Replacing the Roller Assembly Kit
You need to replace the parts on the Roller Assembly Kit after scanning every 100,000 times.
Removal part
|
Part number
|
Number of scanning
|
Roller Assembly Kit
|
B12B813481
|
100,000
|
To replace the Roller Assembly Kit, follow the steps below.
|
Turn off the scanner.
|
|
Remove all paper from the input tray.
|
|
Unplug the AC adapter from the product.
|
|
Open the ADF cover.
|
|
Press the hook on both sides of the pickup roller cover, then open the cover.
|
|
Slide and remove the installed pickup roller.
|
|
Attach the new pickup roller to the correct position.
|
Important:
Do not touch the surface of the pickup roller.
|
|
Close the pickup roller cover.
|
|
Press the hook on both sides of the pre-separation pad.
|
|
Press the hook on both sides of the separation pad and remove.
|
|
Attach the new separation pad to the correct position.
|
Insert firmly until you hear it click into place.
Important:
Do not touch the surface of the separation pad.
|
|
Attach the pre-separation pad as shown in the illustration.
|
|
Close the scanner cover.
|
|
Plug the AC adapter, and then turn on the scanner.
|
|
Start Epson Scan Settings.
|
Windows:
Start > All Programs or Programs > EPSON > EPSON Scan > Epson Scan Settings
Mac OS X:
Select Applications > EPSON Software > EPSON Scan Settings.
|
Click Maintenance.
|
|
Click Reset, and then click OK.
|
Important:
Make sure you reset the counter after replacing the Roller Assembly Kit.
|
| |